The Quality page shows some general statistics on the imported VCF (only for SNVs). It is available through the drop-down menu next to the sample name on top of the screen.

Image RemovedImage Added
Info

Determination of the quality parameters is only based on calls with a “PASS” or empty indication (“.”) in the VCF’s Filter field. Calls with other information in the VCF’s Filter field are not considered by Moon for annotation and analysis.

For some of the provided parameters, Moon indicates whether the value is within the expected range or not (green: expected range, red: deviating from the expected value). Hovering over each icon gives you some more information on the expected range.

The following parameters are provided:

  • Total number of called variants in the VCF with the indication of the number of SNVs and indels

  • Heterozygous/homozygous ratio

  • Transition/transversion ratio

  • % variants with allelic imbalance

  • Average depth of coverage

  • Median depth of coverage

  • Maximum depth

  • Depth distribution diagram

Note

Low quality input VCF files might lead to false positive and false negative interpretation results. It is recommended to assess the overall quality of the input VCF prior to variant interpretation.